huntington beach banner
File #: 23-783   
Type: Public Hearing Status: Agenda Ready
File created: 9/14/2023 In control: Zoning Administrator
On agenda: 9/20/2023 Final action:
Title: CONDITIONAL USE PERMIT NO. 23-008/COASTAL DEVELOPMENT PERMIT NO. 23-004 (OCSD DIGESTER FACILITY AND PERIMETER WALL) REQUEST: To construct a new digester facility within the southern portion of an existing industrial facility consisting of: 1) six digester tanks up to 50 ft. in height; 2) 11,438 sq. ft. of batch tanks up to 48 ft. in height; 3) a 3,000 sq. ft. digester feed/electric building up to 31 ft. in height; 4) a 1,500 sq. ft. cooling tower facility up to 32 ft. height; 5) a 4,500 sq. ft. boiler facility up to 32 ft. in height; 6) two covered tanks up to 38 ft. in height; and 7) an 8,500 sq. ft. warehouse at 29 ft. in height, with a reduced front setback of 19 ft. in lieu of 20 feet. A new block wall (1,070 linear ft.), varying between 8ft. and 11 ft. in height, in lieu of the maximum height of 6 ft., is proposed along the southerly property line of the facility, along with landscape, bike path, and sign improvements. LOCATION: 22212 Brookhurst St., 92646 (east side of Bro...
Attachments: 1. ATT#1 - Suggested Findings and Conditions, 2. ATT#2 - Plans 7.10.23
Date Action ByActionResultAction DetailsMeeting DetailsVideo
No records to display.
ZONING ADMINISTRATOR STAFF REPORT

TO: Zoning Administrator
FROM: Joanna Cortez, Senior Planner

SUBJECT:
title
CONDITIONAL USE PERMIT NO. 23-008/COASTAL DEVELOPMENT PERMIT NO. 23-004 (OCSD DIGESTER FACILITY AND PERIMETER WALL)

REQUEST:
To construct a new digester facility within the southern portion of an existing industrial facility consisting of: 1) six digester tanks up to 50 ft. in height; 2) 11,438 sq. ft. of batch tanks up to 48 ft. in height; 3) a 3,000 sq. ft. digester feed/electric building up to 31 ft. in height; 4) a 1,500 sq. ft. cooling tower facility up to 32 ft. height; 5) a 4,500 sq. ft. boiler facility up to 32 ft. in height; 6) two covered tanks up to 38 ft. in height; and 7) an 8,500 sq. ft. warehouse at 29 ft. in height, with a reduced front setback of 19 ft. in lieu of 20 feet. A new block wall (1,070 linear ft.), varying between 8ft. and 11 ft. in height, in lieu of the maximum height of 6 ft., is proposed along the southerly property line of the facility, along with landscape, bike path, and sign improvements.

LOCATION:
22212 Brookhurst St., 92646 (east side of Brookhurst St., north of PCH)
body

APPLICANT/
PROPERTY
OWNER:
Andrew Brown, Orange County Sanitation District, 10844 Ellis Ave., Fountain Valley, CA 92708



STAFF RECOMMENDATION:
recommendation
That the Zoning Administrator take the following actions:

A) Approves Conditional Use Permit No. 23-008 and Coastal Development Permit No. 23-004 with suggested findings and conditions of approval.
end

General Plan:
P (Public)

Zone:
IL-CZ (Industrial Limited - Coastal Zone)

Environmental Status:
Covered by the Orange County Sanitation District Facilities Master Plan, certified by the OCSD on December 2020. In accordance with CEQA Guidelines Sections 15162 and 15163, no subsequent or supplement to the EIR need be prepared for this project, and no further environmental review or documentation is required.

Coastal Status:
Appealable

Existing Use:
Industrial